i250 i260 i280 Scanner Support

This product is no longer sold as new

Driver e software

Firmware

Download the latest firmware for the i200 Series Scanners here

Before downloading new firmware to the scanner, please download and install the latest version of the i200 Series Scanner Driver. After installing the latest drivers on your Host PC, then return to this page, to upgrade the Firmware as follows:

Installation Instructions

  1. Click on i200 Firmware and download the file to a temporary directory on your C drive.

  2. Double click on the file to extract the firmware files. By default the files are placed in the "C:/Temp" directory. Or, you can enter the directory of your choice. For ease of installation we recommend using C:\WINNT\twain_32\kodak\kds_i200\Firmware.

  3. Click on the "Unzip" button to extract the files. You can now delete the i200FW_vxxxxx.exe file to save space on your PC.

  4. Next, use the Scan Validation Tool to download the i200_xxxxxx.ekpgfw file from the directory selected in the previous step. You will find the Download button under the Setup tab of the SVT.

  5. After the download has completed, power the scanner off, and then back on.

  6. To activate the new features of the scanner you MUST perform a scanner calibration. We strongly recommend you do this immediately after installing the firmware and rebooting.

IMPORTANT Note for KODAK Capture Software Users

  • If you install the latest SVT 5.24 and Firmware 2.5.5 you must use KODAK Capture Software Version 6.6 or higher in order for the scanner to work properly. Download the Lite version of Capture Software. To upgrade to the latest Full version of Capture Software, contact your Regional (local) Kodak Support Center.

The Firmware version can be checked by selecting the "Info" tab of the SVT.

By downloading from Kodak, you agree to the terms & conditions outlined in the license agreement. Actual filesize for multilanguage downloads may vary.

Install Software and Brightness Controls

Installing the scanner drivers from the link on the bottom of this page will install the latest SVT (Scanner Validation Tool), TWAIN Data Source and the latest ISIS Driver for the i200 Series Scanners.

All i200 Series Scanners, with or without the Flatbed Accessory, should be brought up to this level of Host Software, and the Firmware MUST be updated to v 2.5.5 i200 Firmware after the new driver is installed. If this isn't done the scanner will not work properly.

Software Driver CD Version 3.18 included with the latest SVT - July 2007

i250, i260 and i280 Scanner:

  • ISIS driver 1.1.10506.20001
  • SVT 5.24
  • TWAIN v6.65.8
  • STI driver v2.5 (signed)

IMPORTANT NEW FEATURES OF THIS SOFTWARE

  • Adds the ability to accept custom color tables created with the Brightness and Contrast Control
  • Adds iThresholding feature to the i250 and i260 scanners.
  • Allows the i280 to scan as a single image documents up to 34" long.
  • After SVT is installed, a reboot is required.
  • SVT will no longer overwrite newer versions, you MUST UNINSTALL to load "older" versions
By downloading from Kodak, you agree to the terms & conditions outlined in the license agreement. Actual filesize for multilanguage downloads may vary.

Integration

The Kodak TWAIN Integrator Kit contains contains information required to write TWAIN enabled applications for Kodak Alaris' document scanners. This documentation includes custom CAPablities and header files for the Kodak Data Source. This file also contains information on the custom properties exposed by Kodak Alaris' WIA driver.

By downloading from Kodak Alaris, you agree to the terms & conditions outlined in the license agreement. Actual filesize for multilanguage downloads may vary.


Specifications

Recommended Daily Volume
Up to 5,000 pages per day
Throughput Speeds: (Landscape, Letter Sized, Bitonal, Grayscale, Color)
Duplex:
  • Up to 67 pages per minute/134 images per minute at 150 dpi
  • Up to 50 pages per minute/100 images per minute at 200 dpi
  • (Throughput speeds may vary depending on your choice of driver, application software, operating system and PC.)
    Scanning technology
    Dual Tricolor Plus CCD
  • Grayscale output bit depth is 256 levels (8-bit)
  • Color capture bit depth is 40-bit (10 bits per red, green, blue and black channels)
  • Color output bit depth is 24-bit
  • Optical resolution
    300 dpi
    Illumination
    Single long-life Xenon lamp
    Output resolutions
    75,100,150, 200, 240, 300, 400, 600 dpi
    Maximum document size
  • With 64 MB of on-board memory: 297 mm x 432 mm (11.7 in. x 17 in.)
  • With 256 MB of on-board memory: 297 mm x 660 mm (11.7 in. x 26 in.)
  • Dockable flatbed accessory: 297 mm x 432 mm (11.7 in. x 17 in.)
  • Minimum document size
    64 mm x 89 mm (2.5 in. x 3.5 in.)
    Paper thickness and weight
    Onionskin to card stock
    Feeder
    Automatic Document Feeder for continuous loading of up to 150 sheets of 60 g/m2 (16 lb.) paper
    Multi-Feed Detection
    Multi-feed detection with ultrasonic technology
    Connectivity
    IEEE-1394 (FIREWIRE) Interface (card and cable included), 6-pin connector
    Bundled Software
  • TWAIN and ISIS drivers
  • KODAK Capture Software Lite
  • Imaging Features (in the scanner)
  • Perfect Page Scanning with iThresholding
  • Autocrop
  • Aggressive Crop
  • Deskew
  • Electronic Color Dropout
  • dual stream scanning
  • Halftone Removal
  • Noise Removal
  • VRS Compatible
  • On-board compression
    CCITT Group IV; JPEG or uncompressed output
    File Format Outputs
  • JPEG (for color and grayscale images)
  • TIFF (for bitonal images)
  • Electrical Requirements
    100-240 V; 50-60 Hz; universal power supply included
    Power Consumption---Running:
  • 100W typical
  • 180W maximum
  • ENERGY STAR: <12W
  • Environmental Factors
    Mercury-free Xenon lamps
  • Operating temperature: 15-30° C (59-86° F)
  • Operating humidity: 15% to 76% RH
  • Acoustical Noise (operator position Sound Pressure level)
    Standby mode: 39.7 dB(A)
  • Operating mode: 57.0 dB(A)
  • PC Configuration
    Minimum: PENTIUM III 1 GHz processor, 256 MB RAM
  • Recommended: PENTIUM IV 2.4 GHz processor, 512 MB RAM
  • Supported Operating Systems
  • WINDOWS 98SE
  • WINDOWS ME
  • WINDOWS 2000
  • WINDOWS XP
  • Approvals and product certifications
    UL 60950 3rd Edition, C-UL CAN/CSA-C22.2 No. 60950-00 3rd Edition, TUV EN 60950, CE Mark, 47 CFR Part 15 Subpart B (FCC) Class A, ICES-003 Issue 3 Class A, EN 55022:98 Class B**, EN 61000-3-2 Powerline Harmonics, EN 61000-3-3 Flicker, EN 55024, AS/NZS 3548 Class A (C-Tick Mark), CNS 13438 Class A, VCCI Class A, CISPR 22 Class B**
    Consumables Available
  • Feed Module
  • Separator Module
  • Imprinter ink cartridge and blotters
  • Calibration Targets
  • Accessories
  • Dockable flatbed
  • Post-scan document imprinter
  • Dimensions and Weight (scanner)
  • Height: 354 mm (14 in.)
  • Width: 625 mm (24.8 in.)
  • Depth: 287 mm (11.3 in.)
  • Weight: 13.9 kg (30.5 lbs.)
  • Dimensions and Weight (dockable flatbed)
  • Height: 162.5 mm (6.4 in.)
  • Width: 486 mm (19.1 in.)
  • Length: 643 mm (25.3 in.)
  • Weight: 7.3 kg (16 lbs.)
  • Specifications are subject to change without notice. Throughput speeds may vary depending on your choice of driver, application software, operating system and PC.

    Operating System Compatibility

     

    Operating System Compatibility Definitions

    Supported – Kodak Validated

    • Windows 98SE
    • Windows ME
    • Windows 2000
    • Windows XP Pro SP2/SP3 (32-bit and 64-bit)
    • Windows Vista SP1 (32-bit and 64-bit)

    Not Supported – Customer Validated

    • Windows 7 SP1(32-bit and 64-bit)

    Not Supported – Not Validated

    • Windows 95
    • Windows NT
    • Windows 2003 Server x64 Edition
    • Windows 2008 Server  x64 Edition
    • Windows 8.x (32-bit)
    • Windows 8.x (64-bit)
    • Linux
    • Mac

    NOTES:

    FOR Windows 98SE ONLY, USE THIS UNINSTALL PROCEDURE

    1. Run the Uninstaller (Note: For all other Operating Systems, the Uninstall is complete and correct, go to step 8)
    2. Delete the following directory/folder and any sub-directories/folders:
      C:\windows\twain_32\kodak\kds_i200
    3. Delete the following directory/folder and any sub-directories/folders:
      C:\Program Files\Kodak\Document Imaging
    4. Delete file: C:\windows\system\kdssti.dll
    5. Delete file: C:\windows\inf\other\kdssti.inf (Note: inf is a hidden directory)
    6. Delete file: C:\windows\system32\drivers\kdsmm.sys
    7. Delete files: C:\windows\PIXTRAN\Eki200*.*
    8. Restart Windows
    9. Install the required version of SVT

    FOR Windows 7 32-bit ONLY, USE THIS PROCEDURE

    Accessing Device Manager and Device list:

    1. Right click the Computer icon
    2. Select Manage from the list that pops up. The Computer Management window will appear
    3. Select Device Manager from the list on the left of the window
    4. Double click "IEEE 1394 Bus host controllers" from the device list.
    5. Verify driver files:
    • If the device name is "1394 OHCI Compliant Host Controller (Legacy)", verify the correct files are installed. Otherwise proceed to Installation of Driver Files below.

    Driver Verification

    1. Double click the "1394 OHCI Compliant Host Controller (Legacy)", device name. The controller properties window will open.
    2. Select the Driver tab.
    3. Left click Driver Details button from the window.
    4. Check that the Driver files list shows 2 files:
      1394bus.sys and ohci1394.sys
    5. If these are the current driver files, you may close out of Computer Management and proceed with testing. If not, close the Driver Details window and continue with the Installation of Driver Files step 2.

    Installation of Driver Files:

    1. Double click the 1394 host controller device name. The controller properties window will open
    2. Select the Driver tab. Click the Update Driver button
      1. Select "Browse ..... software". Click Next
      2. Select "Let me ..... computer". Click Next
      3. Highlight "1394 OHCI Compliant Host Controller (Legacy)" in the driver list.  Click Next
      4. Close the installation finished window when it appears
      5. Click the Driver Details button from the Properties window
      6. Verify the files 1394bus.sys and ohci1394.sys are listed
      7. Close the properties and management windows.

     

    Manuali e guide

    Domande frequenti

    Come ottenere il massimo dai nostri prodotti? Scopri le domande frequenti relative al prodotto.

    Guida

    Hai bisogno di assistenza? Completa il seguente modulo di richiesta informazioni e ti contatteremo.

    Thank you for submitting your information. We will be in touch soon.
    Submit error